HUMAN VIBRATION METER FOR HAND ARM AND WHOLE BODY |
Model |
: |
VC431 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product |
: |
Spain |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fungsi |
: |
Mengukur Paparan Getaran Mesin terhadap tubuh |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Specification : |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Certificates and regulations |
|
|
|
|
|
|
|
|
|
|
|
|
- |
Complies with the following regulations: |
|
|
|
|
|
|
|
|
|
|
- |
ISO 8041:2005 and ISO 8041:2005/Cor1:2007 |
|
|
|
|
|
|
|
|
|
- |
UNE EN ISO 8041:2006 /AC:2009 |
|
|
|
|
|
|
|
|
|
|
|
- |
Mark. Complied with the directive on low voltage 73/23/EEC and direc- |
|
|
|
|
tive CEM 89/336/EEC modified by 93/68/EEC |
|
|
|
|
|
|
|
|
|
The complies with directives 2002/96/EC and 2003/108/EC on WEEE |
|
|
|
|
(Waste Electrical and Electronic Equipment |
|
|
|
|
|
|
|
|
- |
Range of linearity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Hand Arm Application |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
At reference frequency of (80 Hz): acceleration in m/s² |
|
|
|
|
|
|
|
- |
|
|
|
|
|
Band limiting |
|
Wh |
|
|
|
|
|
|
|
|
- |
Upper limit |
|
|
3800 |
|
|
|
0.038 |
|
|
|
|
|
|
|
- |
Lower limit |
|
|
767.6 |
|
|
|
0.038 |
|
|
|
|
|
|
- |
Whole Body Application |
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
At reference frequency of (80 Hz): acceleration in m/s² |
|
|
|
|
|
|
|
- |
|
|
|
|
|
Band limiting |
|
Wh |
|
|
Wk |
|
|
|
|
|
- |
Upper limit |
|
|
380 |
|
|
|
47.918 |
|
293.28 |
|
|
|
|
- |
Lower limit |
|
|
0.0038 |
|
|
|
0.0038 |
|
0.0038 |
|
|
|
- |
Whole Body in Buildings Application |
|
|
|
|
|
|
|
|
|
|
|
- |
At reference frequency of (16 kHz): acceleration in m/s² |
|
|
|
|
|
|
- |
|
|
|
|
|
Band limiting |
|
Wm |
|
|
|
|
|
|
|
- |
Upper limit |
|
|
76 |
|
|
|
25.55 |
|
|
|
|
|
|
|
- |
Lower limit |
|
|
0.00076 |
|
|
|
0.0008 |
|
|
|
|
|
|
- |
Structure Application |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
At reference frequency of (16 kHz): velocity in m/s² |
|
|
|
|
|
|
|
- |
|
|
|
|
|
Band limiting |
|
|
|
|
|
|
|
|
|
|
- |
Upper limit |
|
|
1.0748 |
|
|
|
|
|
|
|
|
|
|
|
|
- |
Lower limit |
|
|
0.000010748 |
|
|
|
|
|
|
|
|
|
|
- |
Maximum error in frequency measurement: 2% |
|
|
|
|
|
|
|
- |
Total noise inherent in environmental conditions |
|
|
|
|
|
|
|
- |
Hand Arm Application, with |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wh |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Total noise |
0.00365 |
|
|
|
|
|
|
|
|
|
|
|
|
- |
Whole Body Application |
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
|
|
|
Wd |
|
|
|
|
Wk |
|
|
|
|
|
|
|
|
|
|
- |
Total noise |
0.00191 |
|
|
0.00181 |
|
|
|
|
|
|
|
|
- |
Whole Body in Buildings Application, with |
|
|
|
|
|
|
|
|
|
- |
|
|
|
Wm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Total noise |
0.00012 |
|
|
|
|
|
|
|
|
|
|
|
|
- |
Frequency weighting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Hand Arm (HA): Wh |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Whole Body (WB): Wd, Wk |
|
|
|
|
|
|
|
|
|
|
|
|
- |
Whole Body in buildings (WBB): Wm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Acessories : |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Kabel data to computer |
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Software |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Carying case |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Sensor Whole Body & Hand arm |
|
|
|
|
|
|
|
|
|
|
|
- |
Sensor Hand Arm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
Kartu garansi selama 1 tahun |
|
|
|
|
|
|
|
|
|
|
|
|