• rofiq07@hotmail.com

HUMAN VIBRATION METER FOR HAND ARM AND WHOLE BODY

  • Merk : Cesva
  • Minimal Pembelian : 1 UNIT
  • Maksimal Pembelian : 100 UNIT
  • Pengiriman : 3 Hari Setelah Pembayaran
  • Lokasi : DKI Jakarta - Jakarta Timur
  • Harga : KONTAK KAMI
  • Dilihat : 87 Kali
  • Pembaruan : 11-02-2021 09:35

Dapatkan Spesifikasi Harga HUMAN VIBRATION METER FOR HAND ARM AND WHOLE BODY Produk Terbaik dari PT. ABADI KESLING INDONESIA ENVIRONMENTAL, HEALTH & SAFETY EQUIPMENT

Produk Detail

HUMAN VIBRATION METER FOR HAND ARM AND WHOLE BODY   adalah Alat untuk Mengukur Paparan Getaran Mesin terhadap tubuh

HUMAN VIBRATION METER FOR HAND ARM AND WHOLE BODY             
Model : VC431                              
Product : Spain                              
Fungsi : Mengukur Paparan Getaran Mesin terhadap tubuh            
                                       
Specification :                                
- Certificates and regulations                        
- Complies with the following regulations:                  
  - ISO 8041:2005 and ISO 8041:2005/Cor1:2007                
  - UNE EN ISO 8041:2006 /AC:2009                    
  - Mark. Complied with the directive on low voltage 73/23/EEC and direc-    
    tive CEM 89/336/EEC modified by 93/68/EEC              
    The complies with directives 2002/96/EC and 2003/108/EC on WEEE    
    (Waste Electrical and Electronic Equipment                
- Range of linearity                            
- Hand Arm Application                          
  - At reference frequency of (80 Hz): acceleration in m/s²            
  -           Band limiting   Wh              
  - Upper limit     3800       0.038            
  - Lower limit     767.6       0.038            
- Whole Body Application                        
  - At reference frequency of (80 Hz): acceleration in m/s²            
  -           Band limiting   Wh     Wk        
  - Upper limit     380       47.918   293.28      
  - Lower limit     0.0038       0.0038   0.0038      
- Whole Body in Buildings Application                    
  - At reference frequency of (16 kHz): acceleration in m/s²          
  -           Band limiting   Wm            
  - Upper limit     76       25.55            
  - Lower limit     0.00076       0.0008            
- Structure Application                          
  - At reference frequency of (16 kHz): velocity in m/s²            
  -           Band limiting                  
  - Upper limit     1.0748                      
  - Lower limit     0.000010748                  
  - Maximum error in frequency measurement: 2%              
- Total noise inherent in environmental conditions              
- Hand Arm Application, with                       
          Wh                            
  - Total noise 0.00365                        
- Whole Body Application                        
  -       Wd         Wk                  
  - Total noise 0.00191     0.00181                
- Whole Body in Buildings Application, with                 
  -       Wm                          
  - Total noise 0.00012                        
- Frequency weighting                            
  - Hand Arm (HA): Wh                          
  - Whole Body (WB): Wd, Wk                      
  - Whole Body in buildings (WBB): Wm                  
                                       
Acessories :                                  
- Kabel data to computer                          
- Software                                
- Carying case                              
- Sensor Whole Body & Hand arm                      
- Sensor Hand Arm                             